Skip to content
Al-Shaker for Scientific and Medical Supplies

Empty Affinity Chromatography (AC) Column Kits

Kits containing tubes, frits, caps, plunger, syringe and connecting pipe so users can pack their own affinity media in 1 to 300 mL columns.

Key specifications

Components
Empty tubes, frits, upper and bottom caps, plunger, syringe and connecting pipe
006001 / 006002 / 006003 / 006004
1 / 3 / 6 / 12 mL columns; 10 sets/box
006005 / 006006
30 mL / 60 mL columns; 5 sets/box
006009-1
150 mL columns; 5 sets/box
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Biocomma Empty Affinity Chromatography (AC) Column Kits provide everything needed for manual column packing: empty tubes, frits, upper and bottom caps, a plunger, a syringe and a connecting pipe.

The packing procedure given on the page has five steps: pretreat the frits in deionized water or 20% ethanol to remove bubbles, seat the bottom frit with the plunger and cap the outlet, transfer the resin and let it settle, push in the top frit, then fill the column with a suitable solvent, avoid bubbles, and seal both ends for storage.

Kits are available for 1, 3, 6, 12, 30, 60, 150 and 300 mL columns, plus a 1 mL Luer-inlet kit.

Specifications

Technical specifications

7 parameters

Kit contents

Components
Empty tubes, frits, upper and bottom caps, plunger, syringe and connecting pipe

1-12 mL kits

006001 / 006002 / 006003 / 006004
1 / 3 / 6 / 12 mL columns; 10 sets/box

Large kits

006005 / 006006
30 mL / 60 mL columns; 5 sets/box
006009-1
150 mL columns; 5 sets/box
006008
300 mL columns; 3 sets/box

Luer-inlet kit

006007
1 mL Luer-inlet columns; 10 sets/box

Packing

Frit pretreatment
Deionized water or 20% ethanol to remove bubbles
Features

Key features

  • 01

    Complete kit

    Tubes, frits, caps, plunger, syringe and connecting pipe in one set.

  • 02

    Simple manual packing

    A five-step procedure from frit pretreatment to sealed storage.

  • 03

    Wide volume range

    1 mL up to 300 mL column kits.

  • 04

    Luer-inlet option

    A 1 mL kit for Luer-inlet columns (006007).

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.