Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 3

G25 Desalting Cartridges and Plates

Dextran G-25 gel-filtration cartridges and a 96-well centrifugal plate for desalting proteins above 5 kDa and nucleic acids longer than 10 bp/nt.

Key specifications

Separation principle
Gel filtration on Dextran G-25 (size-based separation)
Application range
Proteins larger than 5 kDa or nucleic acids longer than 10 bp/nt
Storage temperature
2-8 °C
DG25003 / DG25003-1
0.8 mL/3 mL and 1.5 mL/3 mL; 50 pcs/pack
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Biocomma G-25 desalting cartridges and plates use Dextran G-25 gel-filtration media to separate molecules by size. Larger molecules are excluded from the gel pores and elute first, while small molecules enter the pores and elute later, which separates biomolecules from salts and other small impurities.

They are intended for the purification and desalting of proteins larger than 5 kDa and nucleic acids longer than 10 bp/nt. Cartridges are listed in a range of bed and total volumes, together with a 96-well centrifugal plate, and are stored at 2-8 °C.

Specifications

Technical specifications

10 parameters

Performance

Separation principle
Gel filtration on Dextran G-25 (size-based separation)
Application range
Proteins larger than 5 kDa or nucleic acids longer than 10 bp/nt

Storage

Storage temperature
2-8 °C

Cartridges

DG25003 / DG25003-1
0.8 mL/3 mL and 1.5 mL/3 mL; 50 pcs/pack
DG25006
2 mL/6 mL; 40 pcs/pack
DG25012 / -1 / -2
4 mL/12 mL, 6 mL/12 mL and 8 mL/12 mL; 20 pcs/pack
DG25005
2.1 mL/5 mL; 40 pcs/box
DG25008
3.5 mL/8.5 mL; 40 pcs/box
DG250013
8.3 mL/13.5 mL; 20 pcs/box

Plate

DG2596003
96-well G25 desalting centrifugal plate, 500 µL/1.0 mL; 6 pcs/box
Features

Key features

  • 01

    Size-based separation

    Dextran G-25 gel filtration separates larger molecules from salts and small contaminants.

  • 02

    Defined application range

    For proteins above 5 kDa and nucleic acids longer than 10 bp/nt.

  • 03

    Many volume options

    Cartridges from 0.8 mL/3 mL up to 8.3 mL/13.5 mL.

  • 04

    96-well format

    Centrifugal plate with 500 µL/1.0 mL wells for parallel desalting.

  • 05

    Cold storage

    Store at 2-8 °C.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.