Skip to content
Al-Shaker for Scientific and Medical Supplies

GST Copure FF Prepacked Columns

Ready-to-use 1 mL and 5 mL columns prepacked with GST Copure FF medium for one-step, high-resolution purification of GST-tagged proteins.

Key specifications

Prepacked medium
GST Copure FF
Particle diameter
90 µm
Loading value
> 12 mg
Max. flow rate
4 (1 mL columns); 20 (5 mL columns) mL/min
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

GST Copure FF Prepacked Columns contain GST Copure FF medium for one-step, high-resolution purification of glutathione S-transferase (GST)-tagged proteins. They belong to Biocomma's family of prepacked protein purification columns, intended to simplify purification, desalting and concentration of antibodies, recombinant proteins and other biological macromolecules.

The columns are offered in 1 mL and 5 mL volumes and connect easily to syringes, peristaltic pumps or liquid-phase purification systems such as ÄKTA. The medium has a 90 µm particle diameter and a maximum pressure of 0.5 MPa, with flow rates up to 4 mL/min on 1 mL columns and 20 mL/min on 5 mL columns.

Specifications

Technical specifications

10 parameters

Medium

Prepacked medium
GST Copure FF

Performance

Particle diameter
90 µm
Loading value
> 12 mg
Max. flow rate
4 (1 mL columns); 20 (5 mL columns) mL/min
Max. pressure
0.5 MPa
pH range
3-12

Ordering

P-AC0201-11
1 x 1 mL
P-AC0201-51
5 x 1 mL
P-AC0201-15
1 x 5 mL
P-AC0201-55
5 x 5 mL
Features

Key features

  • 01

    GST-tag purification

    One-step, high-resolution purification of GST-tagged proteins.

  • 02

    Prepacked and ready to use

    Saves time and labor compared with packing columns manually.

  • 03

    1 mL and 5 mL

    Single columns or packs of five.

  • 04

    Flexible connection

    Works with syringes, peristaltic pumps and systems such as ÄKTA.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.