Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: TJ017F

Hemin

Hemin growth-factor supplement for Peptone Yeast Glucose (PYG) Broth, used in work on fermentation reactions and metabolic end-products of anaerobic bacteria.

Key specifications

Product code
TJ017F
Application
Determination of fermentation reactions and metabolic end-products of anaerobic bacteria
Preparation
Add one vial each of TJ017F and TJ018F to every 100 mL of Peptone Yeast Glucose (PYG) Broth Base (GF1083F/KL1083F).
Hemin
2.5 mg/vial
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Hemin (TJ017F) is a vial supplement for Peptone Yeast Glucose (PYG) Broth. It is used together with Vitamin K1 (TJ018F): one vial of each is added to every 100 mL of PYG Broth Base.

The supplemented broth supports determination of fermentation reactions and metabolic end-products of anaerobic bacteria. Each vial contains 2.5 mg of hemin.

Specifications

Technical specifications

7 parameters

General

Product code
TJ017F
Application
Determination of fermentation reactions and metabolic end-products of anaerobic bacteria
Preparation
Add one vial each of TJ017F and TJ018F to every 100 mL of Peptone Yeast Glucose (PYG) Broth Base (GF1083F/KL1083F).
Storage
Store in a dark and dry place at 2-8 °C.
Shelf life (sealed)
1 year
Precautions
Not for clinical use. Autoclave contaminated materials at 121 °C for 30 minutes before disposal.

Composition

Hemin
2.5 mg/vial
Features

Key features

  • 01

    Anaerobe metabolism work

    Supports determination of fermentation reactions and metabolic end-products of anaerobic bacteria.

  • 02

    Companion supplement

    Dosed together with Vitamin K1 (TJ018F), one vial of each per 100 mL of PYG Broth Base.

  • 03

    Defined content

    Each vial contains 2.5 mg hemin.

  • 04

    Storage

    Store in a dark, dry place at 2-8 °C; sealed shelf life is 1 year.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.