Key specifications

Prepacked medium
SP Copure HP (strong cation exchanger)
Particle diameter
40 µm
Loading value
55 mg ribonuclease
Max. flow rate
4 (1 mL columns); 20 (5 mL columns) mL/min
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

SP Copure HP Prepacked Columns contain SP Copure HP medium, a strong cation exchanger whose relatively small particle size provides efficient, high-resolution purification. They belong to Biocomma's prepacked protein purification column family, aimed at simplifying purification, desalting and concentration of antibodies, recombinant proteins and other macromolecules.

The columns are offered in 1 mL and 5 mL volumes and connect easily to syringes, peristaltic pumps or liquid-phase purification systems such as ÄKTA. The medium has a 40 µm particle diameter, a loading value of 55 mg ribonuclease and a maximum pressure of 0.35 MPa.

Specifications

Technical specifications

10 parameters

Medium

Prepacked medium
SP Copure HP (strong cation exchanger)

Performance

Particle diameter
40 µm
Loading value
55 mg ribonuclease
Max. flow rate
4 (1 mL columns); 20 (5 mL columns) mL/min
Max. pressure
0.35 MPa
pH range
4-13 (1 mL columns); 3-14 (5 mL columns), as listed

Ordering

P-IX0101-11
1 x 1 mL
P-IX0101-51
5 x 1 mL
P-IX0101-15
1 x 5 mL
P-IX0101-55
5 x 5 mL
Features

Key features

  • 01

    High-resolution cation exchange

    Smaller particles give efficient, high-resolution separation.

  • 02

    40 µm particles

    Particle diameter listed as 40 µm.

  • 03

    Loading value

    55 mg ribonuclease.

  • 04

    1 mL and 5 mL

    Single columns or packs of five.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.