Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: TJ012F

Vancomycin Solution

Vancomycin supplement vial for preparing Modified Lauryl Sulfate Tryptose Broth - Vancomycin Medium, used for the selective enrichment of Cronobacter.

Key specifications

Product code
TJ012F
Application
Selective enrichment of Cronobacter
Preparation
Add each vial to every 100 mL of Modified Lauryl Sulfate Tryptose Broth - Vancomycin Medium Base (GF1041F/KL1041F).
Vancomycin
1.0 mg/vial
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Vancomycin Solution (TJ012F) is a single-agent selective supplement. Each vial supplies 1.0 mg of vancomycin and is added to 100 mL of Modified Lauryl Sulfate Tryptose Broth - Vancomycin Medium Base to make the finished enrichment broth.

It is intended for the selective enrichment of Cronobacter and is matched to base product codes GF1041F / KL1041F. A lyophilized 5 mg version of the same antibiotic is listed separately as TJ012RF.

Specifications

Technical specifications

7 parameters

General

Product code
TJ012F
Application
Selective enrichment of Cronobacter
Preparation
Add each vial to every 100 mL of Modified Lauryl Sulfate Tryptose Broth - Vancomycin Medium Base (GF1041F/KL1041F).
Storage
Store in a dark and dry place at 2-8 °C.
Shelf life (sealed)
1 year
Precautions
Not for clinical use. Autoclave contaminated materials at 121 °C for 30 minutes before disposal.

Composition

Vancomycin
1.0 mg/vial
Features

Key features

  • 01

    Cronobacter enrichment

    Added to the base broth to give a selective enrichment medium for Cronobacter.

  • 02

    Simple dosing

    One vial is added to every 100 mL of Modified Lauryl Sulfate Tryptose Broth - Vancomycin Medium Base.

  • 03

    Defined content

    Each vial contains 1.0 mg vancomycin.

  • 04

    Storage

    Store in a dark, dry place at 2-8 °C; sealed shelf life is 1 year.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.