Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: MP-200D

Cole-Parmer MP-200D Stuart Digital Melting Point Apparatus

Two-sample digital melting point apparatus up to 300 °C with 1 °C resolution, illuminated magnifier and programmable plateau temperature.

Key specifications

Number of Samples
2
Min Temperature
Ambient
Max Temperature
300 °C
Temperature Accuracy
±1.0°C at 20°C; ±2.5°C at 300°C
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The MP-200D, formerly the Stuart SMP10, is a digital melting point apparatus for routine identification and purity checks of solid samples. Temperature is selected, measured and displayed digitally, so no glass thermometer is needed, and two capillaries can be tested at the same time.

The melt is observed through a magnifying lens with built-in illumination, and the rear feet can be extended to improve the viewing angle. Users set a plateau temperature for unattended rapid warm-up, after which the block heats slowly at 2 °C per minute towards the melting point for better accuracy.

The instrument reaches 300 °C with 1 °C resolution, using a Pt100 sensor and a 3-digit LED display. Stated accuracy is ±1.0 °C at 20 °C and ±2.5 °C at 300 °C.

Specifications

Technical specifications

15 parameters

Number of Samples
2
Min Temperature
Ambient
Max Temperature
300 °C
Temperature Accuracy
±1.0°C at 20°C; ±2.5°C at 300°C
Temperature Resolution
1°C
Heat-Up Time
20°C per minute; 2°C per minute to melt
Temperature Sensor
100Ω Pt RTD
Display
3-digit LED
Height
17 cm
Depth
22 cm
Width
16 cm
Supply voltage
240 V AC
Frequency
50 Hz
Power consumption
75 W
Warranty
3 years
Features

Key features

  • 01

    Digital temperature control

    No mercury or glass thermometer required.

  • 02

    Two samples at once

    Test duplicate capillaries simultaneously.

  • 03

    Illuminated magnifier

    Clear view of the melt; adjustable viewing angle.

  • 04

    Plateau warm-up

    Unattended fast heating to a preset temperature.

  • 05

    2 °C/min ramp

    Slow final approach to the melt for accuracy.

  • 06

    Up to 300 °C

    1 °C resolution with a Pt100 sensor.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.