Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: Air Shower

Air Shower

Cleanroom air shower from Kesar using 20-25 m/s HEPA-filtered air jets to remove dust from personnel before they enter controlled areas.

Key specifications

Air velocity
20 - 25 m/s
HEPA filter efficiency
99.997 % at 0.3 µm (H-14)
Pre-filter efficiency
95 % at 5 µm
Noise level
≤ 65 dB
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Kesar Air Shower is installed at cleanroom entrances to strip dust and contaminants from clothing and surfaces before personnel enter a controlled area. High-velocity HEPA-filtered air jets dislodge particles so they do not reach the critical environment.

The chamber is SS 304/316 inside with a powder-coated or stainless steel outer body, adjustable stainless steel nozzles, toughened glass doors, a non-slip stainless floor and LED lighting. Air passes through a pre-filter and an H-14 HEPA filter.

A microprocessor or timer control panel runs the cycle with automatic door interlocking and an emergency stop, with an optional touch screen controller. Noise is rated at 65 dB or lower.

Specifications

Technical specifications

7 parameters

Performance

Air velocity
20 - 25 m/s
HEPA filter efficiency
99.997 % at 0.3 µm (H-14)
Pre-filter efficiency
95 % at 5 µm
Noise level
≤ 65 dB

Construction

Air nozzles
Stainless steel
Inner chamber
SS 304 / SS 316

Options

Optional features
UV lamp, door interlock
Features

Key features

  • 01

    High-velocity air jets

    20-25 m/s HEPA-filtered air removes particles from clothing.

  • 02

    Door interlocking

    Automatic interlock between entry and exit doors.

  • 03

    Timer or microprocessor control

    Optional touch screen controller.

  • 04

    Emergency stop

    Emergency stop switch and LED indicators.

  • 05

    Stainless steel construction

    SS 304/316 inner chamber, adjustable nozzles and non-slip floor.

  • 06

    Low noise

    Operating noise of 65 dB or lower.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.