Vacuum drying oven from Kesar (KGOV series, round and rectangular chambers) heating from ambient +50 °C to 200 °C under reduced pressure.

Key specifications

Temperature range
Ambient +50 °C to 200 °C
Accuracy
±2.0 °C
Vacuum range
More than -700 mm of Hg
Control system
Digital PID controller with analog vacuum meter
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Kesar vacuum oven dries, degasses and heat-treats materials under reduced pressure, removing moisture, solvents and volatiles from heat-sensitive samples with less oxidation and thermal decomposition than a conventional oven.

The double-walled stainless steel body with matt finish is insulated with glass wool. The door has a glass viewing window, silicone gasket and positive latch so a vacuum of better than -700 mm Hg can be held while samples are observed. Adjustable stainless steel shelves are included.

A microprocessor PID controller with digital display, an analog vacuum meter, overheat protection and a vacuum control NRV valve for setting the required pressure make up the control side. Round (KGOV-12, 28, 52) and rectangular (KGOV-28, 95, 137) chamber sizes are listed.

Specifications

Technical specifications

10 parameters

Performance

Temperature range
Ambient +50 °C to 200 °C
Accuracy
±2.0 °C
Vacuum range
More than -700 mm of Hg

Control

Control system
Digital PID controller with analog vacuum meter

Models

KGOV-12 (round)
Chamber 9" dia x 12" depth
KGOV-28 (round)
Chamber 12" dia x 15" depth
KGOV-52 (round)
Chamber 15" dia x 18" depth
KGOV-28 (rectangular)
Chamber 12" x 12" x 12" (W x D x H)
KGOV-95 (rectangular)
Chamber 18" x 18" x 18" (W x D x H)
KGOV-137 (rectangular)
Chamber 20" x 20" x 21" (W x D x H)
Features

Key features

  • 01

    Vacuum drying

    Removes moisture and solvents at reduced pressure to protect heat-sensitive samples.

  • 02

    Double-walled stainless steel

    Matt-finish stainless steel inside and out with glass wool insulation.

  • 03

    Sealed viewing door

    Glass window, silicone gasket and positive latch maintain vacuum.

  • 04

    Vacuum control

    NRV valve allows fine adjustment of vacuum pressure; analog vacuum meter.

  • 05

    PID temperature control

    Microprocessor PID with digital display of temperature and vacuum status.

  • 06

    Overheat protection

    Mechanism shuts off the system to prevent excessive heating.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.