RVC 2-25 CDplus

Benchtop rotary vacuum concentrator: 255 × 315 × 460 mm, 24 kg, max 1550 rpm, +30 to +80 °C, 0.2–100 ml, 108 Eppendorf caps.

Key specifications

Dimensions (H × W × D)
255 × 315 × 460 mm
Weight
24 kg
Max. speed
1550 rpm
Set range
+30 to +80 °C
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The RVC 2-25 CDplus is Martin Christ’s compact benchtop midi concentrator for fast, gentle vacuum concentration of DNA/RNA, proteins, and other liquid specimens. Variable-speed magnetic drive, automatic venting, and internal control of vacuum application and release keep samples from splashing. Maximum speed is 1550 rpm; temperature adjusts from +30 to +80 °C. The glass cover resists organic solvents such as TFA and DMSO. The unit is 255 × 315 × 460 mm and 24 kg, with container volumes from 0.2 to 100 ml and up to 108 Eppendorf caps.

Vacuum pumps MZ 2C (end vacuum 8 mbar) or MD 4C (end vacuum 2 mbar) and a wide rotor set configure the concentrator. They are options on this line.

Al-Shaker specifies RVC 2-25 versus a freeze dryer when the method is concentration not lyophilisation, then installs and supports the concentrator across Jordan, the GCC, and MENA.

Specifications

Technical specifications

7 parameters

Installation

Dimensions (H × W × D)
255 × 315 × 460 mm
Weight
24 kg

Performance

Max. speed
1550 rpm

Temperature

Set range
+30 to +80 °C

Capacity

Container volume
0.2–100 ml
Max. Eppendorf caps
108

Vacuum

Pumps
MZ 2C 8 mbar or MD 4C 2 mbar
Features

Key features

  • 01

    Magnetic drive, no splash

    Variable-speed magnetic drive with automatic venting and controlled vacuum release.

  • 02

    Solvent-resistant glass cover

    High resistance to organic solvents such as TFA and DMSO.

  • 03

    MZ 2C or MD 4C

    End vacuum 8 mbar or 2 mbar — the pump stays an option, not a second product.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.