Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: Cypher VRS1250

Cypher VRS1250 Video-Rate Atomic Force Microscope

Full-featured video-rate AFM capturing images at up to 45 frames per second, with 1250 lines per second scan speed and the environmental versatility of the Cypher ES.

Key specifications

Noise floor
<15 pm
Scan speed
Up to 1250 lines/s
Frame rate
Up to 45 frames/s
Mode support
Complete range
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Cypher VRS1250 is presented as the first and only full-featured video-rate AFM, capturing images at up to 45 frames per second while retaining the versatility of the Cypher family. It is aimed at visualising nanoscale dynamics and at demanding multidisciplinary research.

It offers a scan rate of up to 1250 lines per second, a noise floor below 15 pm and the complete range of operating modes, together with the environmental accessories of the Cypher ES: liquid imaging with perfusion, heating, cooling, humidity and electrochemistry. Glovebox integration and high-voltage bias are optional.

Specifications

Technical specifications

7 parameters

Performance

Noise floor
<15 pm
Scan speed
Up to 1250 lines/s
Frame rate
Up to 45 frames/s

Modes

Mode support
Complete range

Environment

Environmental control
Liquid imaging (with perfusion), heating, cooling, humidity, electrochemistry

Options

Glovebox integration
Optional
High-voltage tip/sample bias
Optional
Features

Key features

  • 01

    Video-rate imaging

    Up to 45 frames per second.

  • 02

    Scan speed

    Up to 1250 lines per second.

  • 03

    Ultra-low noise

    Noise floor below 15 pm.

  • 04

    Complete mode range

    Full range of operating modes.

  • 05

    Environmental control

    Liquid perfusion, heating, cooling, humidity and electrochemistry.

  • 06

    blueDrive included

    Photothermal excitation listed as part of the standard configuration.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.