Skip to content
Al-Shaker for Scientific and Medical Supplies

Oxford Instruments MQC-R

Benchtop time-domain NMR at 23 MHz: oil, fat, moisture, protein, fluorine, droplet size — interchangeable 10–26 mm probes, optional >3 T/m gradients, QA software beside the research package.

Key specifications

Frequency
23 MHz time-domain
Diameter
10 to 26 mm (up to 14 mL)
Channels
¹H and ¹⁹F, interchangeable probes
Pulsed field
>3.0 T/m optional — diffusion and 1D profiles
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

MQC-R is Oxford Instruments’ configurable time-domain NMR, not another high-resolution spectrometer. A 23 MHz magnet measures mobility, composition, and mass transport: oil and moisture in food, solid fat, fluorine, amorphous versus crystalline content, emulsion droplet-size distribution. Probes swap from 10 to 26 mm (up to 14 mL) and between ¹H and ¹⁹F. Liquid variable temperature –5 to 70 °C (selected ¹H probes). Pulsed field gradients above 3.0 T/m add diffusion, droplet size, and 1D profiles. Green Imaging research software sits beside Oxford’s QA/QC application pack so the same magnet runs a method in production and a 2D relaxation experiment in development.

Al-Shaker specifies MQC-R versus the production MQC+ when the site needs research gradients, and which probe diameter and nucleus the method actually uses — then installs and supports the analyser. Application methods (oil, SFC, fluorine) are configurations.

X-Pulse remains the high-resolution spectroscopy line. MQC-R is the time-domain instrument you put next to a production lab, not a magnet you cryogen-fill.

Specifications

Technical specifications

4 parameters

Frequency
23 MHz time-domain
Diameter
10 to 26 mm (up to 14 mL)
Channels
¹H and ¹⁹F, interchangeable probes
Pulsed field
>3.0 T/m optional — diffusion and 1D profiles
Features

Key features

  • 01

    Probes you swap, not a second box

    10–26 mm, ¹H or ¹⁹F, up to 14 mL — the magnet stays; the method changes.

  • 02

    Gradients when droplet size is the spec

    Optional >3 T/m pulsed field for diffusion, 1D profiles, and emulsion DSD.

  • 03

    QA pack on the same magnet

    Oxford QC methods for oil, water, solid fat, and fluorine beside the research software.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.