Oxford Instruments X-Pulse 90

The only 90 MHz broadband benchtop NMR: cryogen-free permanent magnet, SpinFlow software, optional 25-position X-Auto — structure and QC on the bench, not in a superconducting hall.

Key specifications

Frequency
90 MHz (2.1 T) permanent magnet
Tuneable range
¹H, ¹⁹F, and broadband ²⁹Si to ³¹P
Linewidth
<0.35 Hz at 50% (20% CHCl₃ in acetone-d6)
Cryogens
None — 2 G line inside the magnet case
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

X-Pulse 90 is Oxford Instruments Magnetic Resonance’s broadband benchtop NMR: 90 MHz (2.1 T) from a permanent magnet, no liquid helium, no quench, 2 G stray field inside the case. Dual-channel and broadband probes cover ¹H, ¹⁹F, and X-nuclei from ²⁹Si to ³¹P — ⁷Li for batteries, ²⁹Si for polymers, ¹³C for APIs — without swapping the spectrometer. Resolution is specified below 0.35 Hz at 50% on 20% CHCl₃ in acetone-d6. Sensitivity on a dual-channel probe is >240:1 for ¹H (1% ethyl benzene). Standard 5 mm tubes, a flow cell, gas variable temperature 0–60 °C, and three-axis pulsed field gradients are the research configuration; X-Auto adds 25 tubes under SpinFlow.

The magnet is 39 × 54 × 43 cm and 115 kg; the electronics 37 × 52 × 26 cm. SpinFlow runs one-click 1D/2D, queues, and a Python pulse-sequence language. Al-Shaker specifies X-Pulse 90 versus the 60 MHz X-Pulse, dual-X versus full broadband, flow versus tubes, and whether X-Auto belongs on day one — then installs, trains, and supports the spectrometer across Jordan, the GCC, and MENA.

Autosamplers, flow cells, and workstations are options on this line.

Specifications

Technical specifications

4 parameters

Frequency
90 MHz (2.1 T) permanent magnet
Tuneable range
¹H, ¹⁹F, and broadband ²⁹Si to ³¹P
Linewidth
<0.35 Hz at 50% (20% CHCl₃ in acetone-d6)
Cryogens
None — 2 G line inside the magnet case
Features

Key features

  • 01

    Broadband without a second magnet

    Tune ¹H, ¹⁹F, and X-nuclei from ²⁹Si to ³¹P on one cryogen-free bench system.

  • 02

    90 MHz splits the overlap

    2.1 T separates peaks a 60 MHz bench still stacks, with enough sensitivity for mass-limited APIs.

  • 03

    X-Auto when the queue is the method

    Twenty-five 5 mm tubes under SpinFlow — overnight nuclei, not an operator on the night shift.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.