Skip to content
Al-Shaker for Scientific and Medical Supplies
Photos available on request

Reference: MQ-Auto

MQ-Auto Robotic Sample Handler for MQC+

Robotic sample handling system for MQC+ TD-NMR analysers that extends operating time for high-throughput or long-measurement applications.

Key specifications

Room temperature racks
Maximum 4
18 mm (8 ml) tubes, room temperature rack
Maximum 50 per rack
26 mm (14 ml) tubes, room temperature rack
Maximum 32 per rack
Heated blocks
Maximum 4
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

MQ-Auto is a robotic system that extends the operating time of the MQC+ TD-NMR analyser. It suits high-throughput or long-measurement applications and frees technicians for other work.

It combines a high-performance robotic arm with configurable sample racks and conditioning stations tailored to each application. Balance and barcode integration are optional for weighing and sample tracking, and the software supports multiple calibrations and lets a run be paused to add samples. A position in each rack must be reserved for the tuning sample.

Specifications

Technical specifications

6 parameters

Racks

Room temperature racks
Maximum 4
18 mm (8 ml) tubes, room temperature rack
Maximum 50 per rack
26 mm (14 ml) tubes, room temperature rack
Maximum 32 per rack
Heated blocks
Maximum 4
18 mm (8 ml) tubes, heated block
Maximum 24 per block
26 mm (14 ml) tubes, heated block
Maximum 18 per block
Features

Key features

  • 01

    Robotic arm

    High-performance arm moves samples between racks, conditioning stations and the magnet.

  • 02

    Configurable racks

    Room temperature racks and heated blocks for 18 mm and 26 mm tubes.

  • 03

    Balance and barcode

    Optional balance and barcode integration for weighing and sample identification.

  • 04

    Multiple calibrations

    Software supports several calibrations in one run and allows pausing to add samples.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.