Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: Vero ES

Vero ES Environmental Atomic Force Microscope

Environmental AFM combining QPDI detection with a fully sealed sample cell for gas and liquid perfusion, heating and cooling from 0 to 250 °C, and fast scanning.

Key specifications

Scan speed
10-100x faster than typical AFMs
Detection technology
Quadrature Phase Differential Interferometry (QPDI)
Sample temperature control range
0 to 250 °C (heating to 250 °C, or heating and cooling 0 to 120 °C)
Gas and liquid
Perfusion through a sealed cell
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Vero ES builds on the Cypher ES and adds QPDI, which measures true tip displacement and lowers cantilever detection noise by up to 10x or more on many cantilevers. It is designed for stable, high-resolution imaging with a noise floor stated as half that of any other AFM and scanning 10 to 100 times faster than typical AFMs.

Fully sealed sample cells enable gas and liquid perfusion with no leak risk and are compatible with fast scanning and all environmental accessories. Temperature control covers 0 to 250 °C in two options (heating to 250 °C, or heating and cooling from 0 to 120 °C), and sample cells keep only fused silica and the PEEK or stainless steel probe clip in contact with liquid for compatibility with harsh chemicals. An optional glovebox configuration supports oxygen- or water-sensitive materials.

It can be upgraded to the Vero VRS1250 for video-rate imaging.

Specifications

Technical specifications

5 parameters

Scan speed
10-100x faster than typical AFMs
Detection technology
Quadrature Phase Differential Interferometry (QPDI)
Sample temperature control range
0 to 250 °C (heating to 250 °C, or heating and cooling 0 to 120 °C)
Gas and liquid
Perfusion through a sealed cell
Upgrade path
Vero VRS1250
Features

Key features

  • 01

    Sealed sample cell

    Gas and liquid perfusion with no leak risk.

  • 02

    Temperature control

    Heating to 250 °C or heating and cooling from 0 to 120 °C.

  • 03

    Chemical compatibility

    Only fused silica and the probe clip contact the liquid.

  • 04

    QPDI detection

    True tip displacement and lower cantilever detection noise.

  • 05

    Glovebox option

    Configuration for oxygen- or water-sensitive materials.

  • 06

    Upgrade path

    Upgradeable to Vero VRS1250.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.