SCION 8700 SQ GC-MS

Single-quadrupole GC-MS with EI and CI, EDR detection, and a 90° Q0 — couples to the 8300 or 8500 GC as a standalone MS or an extra detector.

Key specifications

Type
Single quadrupole (SQ)
Modes
Electron ionisation (EI) and chemical ionisation (CI)
Platforms
SCION 8300 GC and 8500 GC
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The SCION 8700 Single Quadrupole is the GC-MS detector SCION puts on the front of its range: built for fast-paced analytical laboratories that need identification and quantification on the same platform. It supports electron ionisation and chemical ionisation, and mounts on the SCION 8300 or 8500 GC as a dedicated GC-MS or as an additional detector on a multi-channel chromatograph.

The ion path drops lenses and apertures to cut ion losses and leave fewer surfaces to contaminate. An EDR detector covers trace components and high-abundance peaks in one scan, so library search and quantitation sit in the same run. A high-capacity turbopump is specified for the fastest pump-down in this class. A 90° curved Q0 and 90° off-axis detector reduce neutral noise; helium active focusing lifts sensitivity on routine work.

Samplers include the 8400 Pro and 8410 Pro, Versa headspace, CTC PAL, and EST Flex. CompassCDS runs the method. Typical work is pharmaceutical synthesis and QC, chemical identity, environmental VOCs and SVOCs, and food residues.

Al-Shaker specifies 8300 versus 8500, EI versus CI, and the sampler, then installs, tunes, and supports the 8700 across Jordan, the GCC, and MENA.

Specifications

Technical specifications

3 parameters

Type
Single quadrupole (SQ)
Modes
Electron ionisation (EI) and chemical ionisation (CI)
Platforms
SCION 8300 GC and 8500 GC
Features

Key features

  • 01

    EI and CI on the same detector

    Switch ionisation to the compound class instead of owning two mass spectrometers.

  • 02

    Trace and abundant ions in one scan

    EDR detection keeps library-searchable spectra and quantitation together when concentrations span decades.

  • 03

    Couples to 8300 or 8500

    Stand-alone GC-MS or a third detector on a compact or full-size SCION GC, with the same Pro samplers.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.