SCION LC 6000

Modular HPLC with a 6100 quaternary pump (HFM), 6210/6220 autosampler, Peltier ovens, and UV/DAD/FL/RI — CompassCDS with 21 CFR Part 11 tools.

Key specifications

Quaternary
SCION 6100 with High Frequency Mode (HFM)
Models
6210 / 6220, or manual valve
Control
Peltier heat/cool (6310 / 6320)
Options
UV, diode array, fluorescence, refractive index
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The SCION LC 6000 is the liquid chromatograph SCION builds for lifetime performance: accuracy, reliability, and speed with automation that keeps a QC stack running. The 6100 quaternary pump uses High Frequency Mode — double switching of proportioning valves plus real-time feedback — to suppress pulsation so gradients and retention times repeat. Autosamplers 6210 and 6220 use a high-precision syringe drive and a short flow path for injection-volume precision and very low carry-over; a manual valve is offered for teaching or single-shot work.

The 6310 Peltier oven holds three 250 mm columns plus a guard; the 6320 takes three 400 mm or six 150 mm columns. Detectors cover UV, diode array, fluorescence, and refractive index. A low-volume degasser cuts purge solvent; optional plunger wash protects seals on buffered mobile phases. The 6510 organiser holds mixed bottle sizes. CompassCDS provides instrument control, integration, calibration, reporting, and 21 CFR Part 11 support.

Al-Shaker specifies pump, oven, detector, and autosampler for pharmaceutical, food, environmental, and oil-product HPLC, then installs and supports the stack regionally.

Specifications

Technical specifications

4 parameters

Quaternary
SCION 6100 with High Frequency Mode (HFM)
Models
6210 / 6220, or manual valve
Control
Peltier heat/cool (6310 / 6320)
Options
UV, diode array, fluorescence, refractive index
Features

Key features

  • 01

    High Frequency Mode gradients

    The 6100 quaternary pump damps pulsation so retention time is a method property, not a pump artefact.

  • 02

    Injection precision, low carry-over

    6210/6220 syringe drive and a minimised flow path for QC sequences that cannot afford ghost peaks.

  • 03

    Peltier ovens and a full detector set

    Heat and cool the column; choose UV, DAD, fluorescence, or RI without changing manufacturer.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.