SCION Syringes for 8400/8410 Autosamplers

Fixed-needle chromatography syringes from 5 to 250 uL for SCION 8400/8410 autosamplers, with conical needle tips and gastight versions.

Key specifications

Syringe volume range
5 to 250 uL
Needle length
50 mm
Needle gauges
23 G and 26 G, cone tipped
5 UL fixed needle syringe, 23G
41312129
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

SCION qualified syringes are made to fit the 8400 and 8410 series autosamplers. A smooth internal barrel is said to extend syringe life, non-adhesive needle attachment avoids contamination, and the plunger design helps reduce carryover.

Volumes run from 5 to 250 uL for liquid, large volume and gas (headspace) injections, with 50 mm needles whose scale suits SCION inlets. Conical point needles limit septum damage and plasticizer background, 23 gauge needles are sturdier against bending, and gastight versions are offered. Syringes for Rheodyne valves, nanovolume and other autosamplers appear under other syringes.

Specifications

Technical specifications

10 parameters

Volumes

Syringe volume range
5 to 250 uL

Needle

Needle length
50 mm
Needle gauges
23 G and 26 G, cone tipped

Part numbers

5 UL fixed needle syringe, 23G
41312129
10 UL fixed needle syringe, 26G
41312133
10 UL gastight fixed needle syringe, 23G
41312135
25 UL gastight fixed needle syringe, 23G
41312137
50 UL gastight fixed needle syringe, 23G
41312138
100 UL gastight fixed needle syringe, 23G
41312139
250 UL gastight fixed needle syringe, 23G
41312140
Features

Key features

  • 01

    Sizes 5 to 250 uL

    For liquid, large volume and gas injections.

  • 02

    Conical needle tip

    Minimises septum damage and plasticizer background.

  • 03

    23 and 26 gauge needles

    23 gauge for sturdier needles, 26 gauge also listed.

  • 04

    Gastight versions

    Available for gas and headspace work.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.