Reference: HT3

SCION HT3 Static and Dynamic Headspace System

Automated headspace sampler from SCION Instruments with 60-position autosampler, heating up to 300 °C and an optional dynamic mode that raises sensitivity 50 to 100 times.

Key specifications

Integrated autosampler capacity
60 positions
Platen heater
10 positions
Sensitivity gain with Dynamic Headspace option
50 to 100 times (compound dependent)
Maximum temperature
300 °C
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The HT3 is a headspace sampler for GC and GC-MS that works in static mode and, with an added Dynamic Headspace option, in dynamic mode. The dynamic option uses a multi-bed sorbent trap to reach trace-level detection, with SCION quoting a 50 to 100 times sensitivity gain depending on the compound.

A standard 60-position autosampler with a 10-position platen heater gives walk-away automation. The sample pathway, transfer line, needle and loop are inert to limit adsorption and carryover, the sample path is removable for simple maintenance, and temperatures up to 300 °C widen the range of applications. Automated leak check, benchmark testing and a Method Optimization Mode support troubleshooting and method development, and a built-in mass flow controller keeps flow and pressure consistent.

Referenced methods include USP <467>, EPA Method 5021 and RSK-175, with uses across pharmaceutical residual solvents, environmental water, soil and air, food flavour and packaging, and forensic work.

Specifications

Technical specifications

7 parameters

Autosampler

Integrated autosampler capacity
60 positions
Platen heater
10 positions

Performance

Sensitivity gain with Dynamic Headspace option
50 to 100 times (compound dependent)

Temperature

Maximum temperature
300 °C

Flow control

Pneumatics
Built-in Mass Flow Controller

Compliance

Regulatory
21 CFR compliance

Methods

Referenced methods
USP <467>; EPA Method 5021; RSK-175
Features

Key features

  • 01

    60-position autosampler

    Integrated sampler with 10-position platen heater for walk-away operation.

  • 02

    Dynamic Headspace option

    50 to 100 times higher sensitivity depending on the compound.

  • 03

    Inert sample pathway

    Transfer line, needle and loop designed to avoid adsorption and reduce carryover.

  • 04

    High-temperature capability

    Heating up to 300 °C for a broader set of applications.

  • 05

    Automated diagnostics and method development

    Leak check, benchmark test and Method Optimization Mode (M.O.M.).

  • 06

    Built-in mass flow controller

    Consistent flow and pressure regardless of external conditions.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.