Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 4

Reference: 1-14

Sigma 1-14 Microcentrifuge

Compact unrefrigerated microcentrifuge for up to 24 x 2 ml tubes, reaching 16,163 x g at 14,800 rpm, with a motorised lid lock and a wide choice of rotors.

Key specifications

Max. capacity, fixed-angle rotor
24 x 2 ml
Max. RCF
16,163 x g
Max. speed
14,800 rpm
Min. speed
200 rpm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Sigma 1-14 is a compact benchtop microcentrifuge built to fit into any laboratory while still meeting demanding technical requirements. Two fixed-angle rotors hold up to 24 x 1.5/2.0 ml tubes, and further rotors cover PCR strips, microhaematocrit capillary tubes and filter tubes.

It is used for DNA, RNA and protein isolation, clinical chemistry and general work in research labs, food labs, universities and pharmaceutical laboratories. Sigma describes it as quiet even at top speed, with short braking times, simple operation and a motorised lid lock for effortless closing.

A refrigerated version is available as the Sigma 1-14K.

Specifications

Technical specifications

12 parameters

Capacity

Max. capacity, fixed-angle rotor
24 x 2 ml

Performance

Max. RCF
16,163 x g
Max. speed
14,800 rpm
Min. speed
200 rpm
Max. speed / RCF, fixed-angle rotor
14,800 rpm / 16,162 x g
Noise level at max. speed (fixed-angle rotor 12094)
≤ 54 dB(A)
Max. acceleration time (fixed-angle rotor 12094)
≤ 15 s
Max. braking time (fixed-angle rotor 12094)
≤ 12 s

Electrical

Power consumption
95 W

Dimensions & Weight

Height x Width x Depth
176 x 266 x 212 mm
Height with open lid
310 mm
Weight without rotor
6 kg
Features

Key features

  • 01

    Wide rotor range

    Rotors for 1.5/2.0 ml tubes, PCR strips, microhaematocrit capillaries and filter tubes.

  • 02

    Motorised lid lock

    The lid closes effortlessly and locks automatically.

  • 03

    Low noise

    Quiet running even at maximum speed, with a rated level of up to 54 dB(A) for the fixed-angle rotor.

  • 04

    Short run-up and braking

    Acceleration of up to 15 s and braking of up to 12 s with the fixed-angle rotor.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.