Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 4

Reference: 1-14 Think Pink Edition

Sigma 1-14 Think Pink Edition Microcentrifuge

Special-edition Sigma 1-14 microcentrifuge (24 x 2 ml, up to 16,163 x g) for which Sigma donates EUR 50 per device sold to Think Pink Europe.

Key specifications

Max. capacity, fixed-angle rotor
24 x 2 ml
Max. RCF
16,163 x g
Max. speed
14,800 rpm
Min. speed
200 rpm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Think Pink Edition is a special version of the compact Sigma 1-14 microcentrifuge. Technically it offers the same capabilities as the standard model: two fixed-angle rotors for up to 24 x 1.5/2.0 ml tubes, plus rotors for PCR strips, microhaematocrit capillaries and filter tubes.

For every device sold, Sigma donates EUR 50 to the Think Pink Europe organisation in the fight against breast cancer.

It suits molecular biology work such as DNA, RNA and protein isolation, clinical chemistry, research and food labs, universities and pharmaceutical laboratories. It runs quietly, brakes quickly and closes through a motorised lid lock.

Specifications

Technical specifications

12 parameters

Capacity

Max. capacity, fixed-angle rotor
24 x 2 ml

Performance

Max. RCF
16,163 x g
Max. speed
14,800 rpm
Min. speed
200 rpm
Max. speed / RCF, fixed-angle rotor
14,800 rpm / 16,162 x g
Noise level at max. speed (fixed-angle rotor 12094)
≤ 54 dB(A)
Max. acceleration time (fixed-angle rotor 12094)
≤ 15 s
Max. braking time (fixed-angle rotor 12094)
≤ 12 s

Electrical

Power consumption
95 W

Dimensions & Weight

Height x Width x Depth
176 x 266 x 212 mm
Height with open lid
310 mm
Weight without rotor
6 kg
Features

Key features

  • 01

    Charity edition

    EUR 50 per device sold goes to Think Pink Europe.

  • 02

    Compact microcentrifuge

    Up to 24 x 2 ml capacity and 16,163 x g at 14,800 rpm.

  • 03

    Versatile rotors

    PCR strip, microhaematocrit capillary and filter-tube rotors are available.

  • 04

    Motorised lid lock

    Effortless lid closing.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.