Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 4

Reference: 1-16K

Sigma 1-16K Refrigerated Microcentrifuge

Refrigerated microcentrifuge with RCF above 20,600 x g, a closable 36 x 2 ml biosafe rotor, demand-controlled fan cooling and ten stored programs.

Key specifications

Max. capacity, fixed-angle rotor
36 x 2 ml
Max. RCF
20,627 x g
Max. speed
15,000 rpm
Min. speed
200 rpm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Sigma 1-16K is the refrigerated version of the Sigma 1-16. It combines a space-saving design with a high-grade stainless steel bowl, short acceleration and braking times and a motorised lid lock. RCF reaches 20,627 x g at 15,000 rpm, and Sigma states that +4 °C is reliably maintained at maximum speed.

A fan control adapts fan speed to the required cooling capacity, which Sigma says makes the unit noticeably quieter and cuts power consumption. The rotor range covers PCR strips, filter tubes, 2 ml and 5 ml tubes and microhaematocrit capillaries, including a closable 36 x 2 ml biosafe rotor and a 12 x 5 ml rotor.

Ten standard programs can be stored. An IVD model is also available.

Specifications

Technical specifications

15 parameters

Capacity

Max. capacity, fixed-angle rotor
36 x 2 ml

Performance

Max. RCF
20,627 x g
Max. speed
15,000 rpm
Min. speed
200 rpm
Max. speed / RCF, fixed-angle rotor
15,000 rpm / 20,627 x g
Noise level at max. speed (fixed-angle rotor 12134)
≤ 48 dB(A)
Max. acceleration time (fixed-angle rotor 12134)
≤ 16 s
Max. braking time (fixed-angle rotor 12134)
≤ 16 s

Electrical

Power consumption
420 W

Dimensions & Weight

Height x Width x Depth
291 x 310 x 660 mm
Height with open lid
547 mm
Weight without rotor
34 kg

Refrigeration

Refrigerant
R513a
Refrigerant charge / pressure
0.136 / 23 kg / bar
CO2 equivalent
0.086 t
Features

Key features

  • 01

    Refrigerated operation

    Reliably achieves +4 °C at maximum speed.

  • 02

    Fan control

    Fan speed follows cooling demand for lower noise and energy use.

  • 03

    Biosafe rotor

    Closable rotor for 36 x 2 ml tubes.

  • 04

    Program memory

    Ten standard programs can be stored.

  • 05

    Product options

    IVD model, centrifuge package with a 24 x 2 ml rotor, and a 36 x 2 ml biosafe rotor.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.