Sigma 4-16KHS Refrigerated and Heated Benchtop Centrifuge

Benchtop centrifuge with cooling and heating (-20 to +60 °C), up to 4 x 750 ml swing-out or 6 x 250 ml fixed-angle capacity and 25,155 x g, for viscous specimens.

Key specifications

Max. capacity, swing-out rotor
4 x 750 ml
Max. capacity, fixed-angle rotor
6 x 250 ml
Max. RCF
25,155 x g
Max. speed
15,000 rpm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Sigma 4-16KHS refrigerated and heated benchtop centrifuge offers diverse rotor configurations and outstanding capacity: 4 x 750 ml in a swing-out rotor or 6 x 250 ml in a fixed-angle rotor. It suits research labs, hospitals, universities, pharmaceutical labs, cell culture and biotechnology, especially for specimens whose viscosity must be reduced during centrifugation.

The temperature setting range is -20 to +60 °C. Numerous swing-out and fixed-angle rotors, buckets and adapters, including biosafe configurations, take tubes and flasks from 0.2 to 750 ml plus microtiter and deepwell plates. Sigma cites best-in-class RCF for the segment, a 6 x 250 ml rotor at 13,131 x g and 50 ml culture tubes at more than 23,000 x g.

The patented Spincontrol S controller provides 30 acceleration and 30 braking profiles, a process library, automatic rotor identification, run-time and speed monitoring and password-protected access. Options include an inert gas port, clinic and cell culture packages, biosafe rotors and an RS 232 interface.

Specifications

Technical specifications

21 parameters

Capacity

Max. capacity, swing-out rotor
4 x 750 ml
Max. capacity, fixed-angle rotor
6 x 250 ml

Performance

Max. RCF
25,155 x g
Max. speed
15,000 rpm
Min. speed
100 rpm
Max. speed / RCF, swing-out rotor
5,700 rpm / 5,485 x g
Max. speed / RCF, fixed-angle rotor
15,000 rpm / 25,155 x g
Noise level at max. speed (fixed-angle rotor 12449)
≤ 60 dB(A)
Noise level at max. speed (swing-out rotor 11660 + bucket 13450 + Cover)
≤ 59 dB(A)
Max. acceleration time (fixed-angle rotor 12449)
≤ 27 s
Max. acceleration time (swing-out rotor 11660 + bucket 13450 + Cover)
≤ 23 s
Max. braking time (fixed-angle rotor 12449)
≤ 42 s
Max. braking time (swing-out rotor 11660 + bucket 13450 + Cover)
≤ 27 s

Temperature

Temperature setting range
-20 to +60 °C

Electrical

Power consumption
2,000 W

Dimensions & Weight

Height x Width x Depth
489 x 670 x 650 mm
Height with open lid
940 mm
Weight without rotor
124 kg

Refrigeration

Refrigerant
R452A
Refrigerant charge / pressure
0.530 / 25 kg / bar
CO2 equivalent
1.134 t
Features

Key features

  • 01

    Heating and cooling

    Temperature setting range -20 to +60 °C.

  • 02

    Large capacity

    4 x 750 ml swing-out or 6 x 250 ml fixed-angle.

  • 03

    High RCF

    Up to 25,155 x g at 15,000 rpm.

  • 04

    Spincontrol S

    One-knob controller with 30 acceleration and 30 braking profiles.

  • 05

    Options

    Inert gas port, clinic and cell culture packages, biosafe rotors, RS 232.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.