Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 3

Reference: 846

Socorex Acura capillar 846 positive displacement micropipette

Positive displacement micropipette with interchangeable glass capillaries and ETFE-tipped plungers for viscous, foaming or volatile liquids, 1 to 200 µL.

Key specifications

Models
1–5 µL (white, 846.005), 5–25 µL (white, 846.025), 10–50 µL (green, 846.050), 60–100 µL (blue, 846.100), 100–200 µL (red, 846.200)
Principle
Positive displacement with interchangeable glass capillary and ETFE-tipped stainless steel plunger
Volume setting
5 pre-set volumes per model, step-wise and locked
Accuracy, 1–5 µL
Inaccuracy E% <±3.0 % / <±2.3 % / <±2.0 %; Imprecision CV% <2.5 % / <2.0 % / <1.2 %
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura capillar 846 is a positive displacement micropipette: the plunger moves inside a glass capillary and contacts the liquid directly, which suits viscous liquids, foaming solutions and volatile solvents. Five models cover 1 to 200 µL.

Each model offers five pre-set volumes that are changed and locked step by step, and the barrel shows the volume. Pipette, plunger and capillary share a colour code so the volume range is identifiable at once. The plunger is stainless steel with a chemically inert ETFE tip, and the slim shaft reaches into deep, narrow containers.

Specifications

Technical specifications

9 parameters

General

Models
1–5 µL (white, 846.005), 5–25 µL (white, 846.025), 10–50 µL (green, 846.050), 60–100 µL (blue, 846.100), 100–200 µL (red, 846.200)
Principle
Positive displacement with interchangeable glass capillary and ETFE-tipped stainless steel plunger
Volume setting
5 pre-set volumes per model, step-wise and locked
Warranty
3 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 1–5 µL
Inaccuracy E% <±3.0 % / <±2.3 % / <±2.0 %; Imprecision CV% <2.5 % / <2.0 % / <1.2 %
Accuracy, 5–25 µL
Inaccuracy E% <±1.5 % / <±1.2 % / <±0.8 %; Imprecision CV% <1.0 % / <0.9 % / <0.6 %
Accuracy, 10–50 µL
Inaccuracy E% <±1.2 % / <±1.0 % / <±0.7 %; Imprecision CV% <0.8 % / <0.7 % / <0.4 %
Accuracy, 60–100 µL
Inaccuracy E% <±0.7 % at all volumes; Imprecision CV% <0.6 % / <0.5 % / <0.3 %
Accuracy, 100–200 µL
Inaccuracy E% <±0.7 % at all volumes; Imprecision CV% <0.3 %
Features

Key features

  • 01

    Five pre-set volumes

    Instant change and lock of each volume.

  • 02

    ETFE-tipped plunger

    Chemically inert contact with the liquid.

  • 03

    Slim shaft

    Glass capillaries reach deep and narrow containers.

  • 04

    Colour coding

    Pipette, plunger and capillary share one colour per range.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.