Reference: 956

Socorex Acura electro 956 electronic multichannel pipette

8- and 12-channel electronic pipette from 0.5 to 350 µL with sequential tip ejection, six pipetting modes and interchangeable volumetric modules.

Key specifications

Channels
8 and 12
Volume ranges
0.5–10, 2.5–50, 10–200, 20–350 µL (8 and 12 channel)
Resolution (division)
0.05, 0.25, 1.0 and 5.0 µL respectively
Catalogue numbers
956.08.010, .050, .200, .350 (8-ch); 956.12.010, .050, .200, .350 (12-ch); initial packs with suffix E
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura electro 956 is the multichannel version of the Acura electro line, available with 8 or 12 channels in four volume ranges between 0.5 and 350 µL. The control unit is the same microprocessor-controlled unit with rechargeable battery used by the other electro models.

It is light, fits the hand like a manual instrument and has a bowed ejector head for effortless sequential tip ejection. The same six pipetting modes, variable speed, cycle counter and calibration menu are available, and the unit also accepts any single-channel volumetric module.

Initial packs add charging stand, second battery, fast charger and tips.

Specifications

Technical specifications

11 parameters

General

Channels
8 and 12
Volume ranges
0.5–10, 2.5–50, 10–200, 20–350 µL (8 and 12 channel)
Resolution (division)
0.05, 0.25, 1.0 and 5.0 µL respectively
Catalogue numbers
956.08.010, .050, .200, .350 (8-ch); 956.12.010, .050, .200, .350 (12-ch); initial packs with suffix E
Battery
NiMH, charge in <1.5 h, >3000 consecutive cycles
Interchangeable volumetric modules
Also fits any single-channel volumetric module

Pipetting modes

Modes
Forward, reverse, stepper, dilution, tactile, mixing

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 0.5–10 µL
Inaccuracy E% <±3.5 % / <±1.5 % / <±1.0 %; Imprecision CV% <3.0 % / <0.9 % / <0.7 % (min measured at 10 % of nominal)
Accuracy, 2.5–50 µL
Inaccuracy E% <±1.0 % / <±0.9 % / <±0.8 %; Imprecision CV% <1.0 % / <0.6 % / <0.4 %
Accuracy, 10–200 µL
Inaccuracy E% <±0.9 % / <±0.7 % / <±0.6 %; Imprecision CV% <0.6 % / <0.4 % / <0.25 %
Accuracy, 20–350 µL
Inaccuracy E% <±1.0 % / <±0.8 % / <±0.6 %; Imprecision CV% <0.6 % / <0.4 % / <0.25 %
Features

Key features

  • 01

    8- and 12-channel models

    Four volume ranges up to 350 µL.

  • 02

    Sequential tip ejection

    Bowed ejector head for effortless ejection.

  • 03

    Six pipetting modes

    Forward, reverse, stepper, dilution, tactile and mixing.

  • 04

    Variable speed

    Front selector.

  • 05

    Pipetting cycle counter

    Helps monitor maintenance.

  • 06

    Fits single-channel modules

    Interchangeable with single-channel volumetric modules.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.