Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 2

Reference: 815

Socorex Acura manual 815 fixed volume micropipette

Fixed-volume manual micropipette delivering a single pre-set volume between 1 and 1000 µL, removing the risk of wrong volume setting in routine tests.

Key specifications

Fixed volumes (model selection)
1, 5, 10, 15, 20, 25, 30, 32, 40, 50, 60, 70, 75, 80, 90, 100, 150, 200, 250, 300, 400, 500, 600, 700, 750, 800, 900 and 1000 µL
Catalogue numbers
815.0001 (1 µL) to 815.0750 (750 µL), e.g. 815.0010 (10 µL), 815.0100 (100 µL), 815.0200 (200 µL)
Tip style
ultra 10 µL (1–10 µL), 200 µL (10Y–200 µL), 1000 µL (250–750 µL)
Inaccuracy, 1 µL / 5 µL
<±2.0 % / <±1.4 %
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura manual 815 is a fixed-volume micropipette offered in dozens of pre-set volumes from 1 to 1000 µL. Because the volume cannot be mis-set, it suits repeated analytical or routine diagnostic tests where consistency matters most.

It has a slim, lightweight body with soft plunger activation, a colour-coded smartie cap, an adjustable Justip tip ejector and user calibration with an integrated key. The instrument resists shock and UV light and can be autoclaved.

Specifications

Technical specifications

7 parameters

General

Fixed volumes (model selection)
1, 5, 10, 15, 20, 25, 30, 32, 40, 50, 60, 70, 75, 80, 90, 100, 150, 200, 250, 300, 400, 500, 600, 700, 750, 800, 900 and 1000 µL
Catalogue numbers
815.0001 (1 µL) to 815.0750 (750 µL), e.g. 815.0010 (10 µL), 815.0100 (100 µL), 815.0200 (200 µL)
Tip style
ultra 10 µL (1–10 µL), 200 µL (10Y–200 µL), 1000 µL (250–750 µL)
Warranty
3 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Inaccuracy, 1 µL / 5 µL
<±2.0 % / <±1.4 %
Inaccuracy, 10 µL and above
<±0.7 %
Imprecision CV%
<1.0 % at 1 µL, <0.7 % at 10 µL, <0.3 % at 100 µL, <0.2 % at 700 µL
Features

Key features

  • 01

    Fixed volume

    No setting required, removing erroneous volume selection.

  • 02

    Slim and light

    Ergonomic body with soft plunger activation.

  • 03

    Justip tip ejector

    Adjustable shaft height to fit most tips.

  • 04

    User calibration

    Integrated key for in-lab calibration.

  • 05

    Colour-coded cap

    Smartie cap identifies the volume at a glance.

  • 06

    Autoclavable

    Resists shock and UV light.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.