Reference: 825

Socorex Acura manual 825 micropipette

Classic single-channel manual micropipette from Socorex covering 0.1 to 1000 µL in eight models, with adjustable tip ejector and user calibration.

Key specifications

Volume ranges
0.1–2, 0.5–10, 1–10, 2–20, 5–50, 10–100, 20–200 and 100–1000 µL (8 models)
Graduation
0.002 µL (0.1–2 µL) up to 1 µL (100–1000 µL)
Catalogue numbers
825.0002, 825.0010, 825.0010Y, 825.0020, 825.0050, 825.0100, 825.0200, 825.1000
Triopacks
825.TRIO.C, .J, .M, .O, .P, .S, .T, .V (3 pipettes per pack); 835.TRIO.Y
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura manual 825 is the standard single-channel manual micropipette in the Socorex range, intended for routine and general laboratory pipetting. Eight models cover 0.1 to 1000 µL, each with colour-coded cap and a display window that stays visible while pipetting.

Volume is set with the push button using fine click-stops, and the cap rotates freely so the setting cannot be changed by accident. The tip ejector height can be adjusted over a 4 mm span to fit many tip brands, and the pipette can be recalibrated by the user with the integrated key.

The whole instrument can be autoclaved assembled. It is also sold in Triopacks of three volumes with tip samples and QC certificates.

Specifications

Technical specifications

16 parameters

General

Volume ranges
0.1–2, 0.5–10, 1–10, 2–20, 5–50, 10–100, 20–200 and 100–1000 µL (8 models)
Graduation
0.002 µL (0.1–2 µL) up to 1 µL (100–1000 µL)
Catalogue numbers
825.0002, 825.0010, 825.0010Y, 825.0020, 825.0050, 825.0100, 825.0200, 825.1000
Triopacks
825.TRIO.C, .J, .M, .O, .P, .S, .T, .V (3 pipettes per pack); 835.TRIO.Y
Pipette weight
88–95 g
Sterilisation
Autoclavable fully assembled, 121 °C / 250 °F for 20 min
Warranty
3 years
Supplied with
Qualitix tip sample, silicone grease, individual QC certificate, operating instructions

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 0.1–2 µL
Inaccuracy E% <±6.0 % / <±4.0 % / <±2.0 % (min / mid / max volume); Imprecision CV% <5.0 % / <3.3 % / <1.5 %
Accuracy, 0.5–10 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 % (min / mid / max volume); Imprecision CV% <1.8 % / <1.2 % / <0.5 %
Accuracy, 1–10 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 % (min / mid / max volume); Imprecision CV% <2.5 % / <1.6 % / <0.7 %
Accuracy, 2–20 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 % (min / mid / max volume); Imprecision CV% <1.7 % / <1.0 % / <0.5 %
Accuracy, 5–50 µL
Inaccuracy E% <±1.5 % / <±1.3 % / <±1.0 % (min / mid / max volume); Imprecision CV% <1.0 % / <0.7 % / <0.4 %
Accuracy, 10–100 µL
Inaccuracy E% <±1.5 % / <±1.2 % / <±0.8 % (min / mid / max volume); Imprecision CV% <1.0 % / <0.6 % / <0.2 %
Accuracy, 20–200 µL
Inaccuracy E% <±1.5 % / <±1.1 % / <±0.6 % (min / mid / max volume); Imprecision CV% <0.6 % / <0.4 % / <0.2 %
Accuracy, 100–1000 µL
Inaccuracy E% <±1.5 % / <±1.0 % / <±0.5 % (min / mid / max volume); Imprecision CV% <0.5 % / <0.4 % / <0.2 %
Features

Key features

  • 01

    Click-stop volume setting

    Fine click-stops and a free-rotating cap prevent unwanted volume changes.

  • 02

    Always visible display

    Volume window on the front of the instrument.

  • 03

    Justip tip ejector

    4 mm height adjustment to fit a wide selection of tips.

  • 04

    Swift-Set calibration

    User calibration with integrated key and sealed locking switch.

  • 05

    Autoclavable

    Shock, UV-light and chemical resistant; sterilise assembled at 121 °C.

  • 06

    Triopack options

    Three-pipette packs in several volume combinations.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.