Research-oriented lightweight manual micropipette derived from the 825, with a shorter shaft, conical end and ultra-smooth plunger, 0.1 to 1000 µL.

Key specifications

Volume ranges
0.1–2, 0.5–10, 1–10, 2–20, 5–50, 10–100, 20–200 and 100–1000 µL (8 models)
Catalogue numbers
826.0002, 826.0010, 826.0010Y, 826.0020, 826.0050, 826.0100, 826.0200, 826.1000
TwiXS packs
826.TWX.E, .G, .H, .K, .N, .Q (2 pipettes per pack, with free shelf pipette holder)
Pipette weight
84–88 g
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura manual 826 XS is derived from the 825 and designed with research scientists in mind. It is shorter, lighter and smoother in operation, and eight models cover 0.1 to 1000 µL.

A lip seal on the plunger gives very soft activation and reduces hand fatigue, while the short narrow shaft with a conical end makes it easier to reach into small microtubes. The display stays visible on the front, the tip ejector height is adjustable, and the pipette is user-calibratable.

TwiXS packs combine two volumes with a free shelf pipette holder and tip samples.

Specifications

Technical specifications

16 parameters

General

Volume ranges
0.1–2, 0.5–10, 1–10, 2–20, 5–50, 10–100, 20–200 and 100–1000 µL (8 models)
Catalogue numbers
826.0002, 826.0010, 826.0010Y, 826.0020, 826.0050, 826.0100, 826.0200, 826.1000
TwiXS packs
826.TWX.E, .G, .H, .K, .N, .Q (2 pipettes per pack, with free shelf pipette holder)
Pipette weight
84–88 g
Lower assembly
Up to 35 % shorter than the 825
Plunger seal
Leap seal tightness lip for ultra-smooth activation
Sterilisation
Autoclavable fully assembled, 121 °C / 250 °F for 20 min
Warranty
3 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 0.1–2 µL
Inaccuracy E% <±6.0 % / <±4.0 % / <±2.0 % (min / mid / max volume); Imprecision CV% <5.0 % / <3.3 % / <1.5 %
Accuracy, 0.5–10 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 % (min / mid / max volume); Imprecision CV% <1.8 % / <1.2 % / <0.5 %
Accuracy, 1–10 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 % (min / mid / max volume); Imprecision CV% <2.5 % / <1.6 % / <0.7 %
Accuracy, 2–20 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 % (min / mid / max volume); Imprecision CV% <1.7 % / <1.0 % / <0.5 %
Accuracy, 5–50 µL
Inaccuracy E% <±1.5 % / <±1.3 % / <±1.0 % (min / mid / max volume); Imprecision CV% <1.0 % / <0.7 % / <0.4 %
Accuracy, 10–100 µL
Inaccuracy E% <±1.5 % / <±1.2 % / <±0.8 % (min / mid / max volume); Imprecision CV% <1.0 % / <0.6 % / <0.2 %
Accuracy, 20–200 µL
Inaccuracy E% <±1.5 % / <±1.1 % / <±0.6 % (min / mid / max volume); Imprecision CV% <0.6 % / <0.4 % / <0.2 %
Accuracy, 100–1000 µL
Inaccuracy E% <±1.5 % / <±1.0 % / <±0.5 % (min / mid / max volume); Imprecision CV% <0.5 % / <0.4 % / <0.2 %
Features

Key features

  • 01

    Reduced weight

    84–88 g, lighter than the standard 825.

  • 02

    Ultra-smooth activation

    Tightness lip seal with soft springs and a tactile overshoot stop.

  • 03

    Short conical shaft

    Easier reach into small microtubes.

  • 04

    Justip tip ejector

    Adjustable height for a tight fit on many tip types.

  • 05

    Swift-Set calibration

    Integrated key, protected by a seal sticker.

  • 06

    TwiXS packs

    Two-pipette packs with a free shelf pipette holder.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.