Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: 835F

Socorex Acura manual 835F fixed volume macropipette

Fixed-volume manual macropipette in 2, 2.5, 5 and 10 mL versions, giving stable results by removing the possibility of an incorrect volume setting.

Key specifications

Fixed volumes
2 mL, 2.5 mL, 5 mL, 10 mL
Catalogue numbers
835.F02 (2 mL), 835.F02.5 (2.5 mL), 835.F05 (5 mL), 835.F10 (10 mL)
Tip style
2 mL, 5 mL, 5 mL and 10 mL respectively
Inaccuracy E%
<±0.5 % (2 mL), <±0.8 % (2.5 mL), <±0.6 % (5 mL), <±0.5 % (10 mL)
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura manual 835F macropipettes dispense a single pre-set volume of 2, 2.5, 5 or 10 mL. Fixed-volume instruments show the most stable performance and suit analytical or routine diagnostic work where operator error in volume setting must be avoided.

They share the slim, light body of the Acura manual family, with soft plunger activation, an adjustable Justip tip ejector, user calibration with an integrated key, a colour-coded smartie cap and an interchangeable nozzle protection filter.

Specifications

Technical specifications

6 parameters

General

Fixed volumes
2 mL, 2.5 mL, 5 mL, 10 mL
Catalogue numbers
835.F02 (2 mL), 835.F02.5 (2.5 mL), 835.F05 (5 mL), 835.F10 (10 mL)
Tip style
2 mL, 5 mL, 5 mL and 10 mL respectively
Warranty
3 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Inaccuracy E%
<±0.5 % (2 mL), <±0.8 % (2.5 mL), <±0.6 % (5 mL), <±0.5 % (10 mL)
Imprecision CV%
<0.2 % (2 mL), <0.5 % (2.5 mL), <0.3 % (5 mL), <0.2 % (10 mL)
Features

Key features

  • 01

    Fixed volume

    Eliminates erroneous volume setting.

  • 02

    Soft plunger action

    Slim, lightweight ergonomic design.

  • 03

    Justip tip ejector

    Adjustable to fit most tips.

  • 04

    Nozzle protection filter

    Interchangeable filter.

  • 05

    User calibration

    Integrated calibration key.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.