Socorex Acura manual 855 multichannel pipette

8- and 12-channel manual pipette for 96-well microplate work, covering 0.5 to 350 µL, with rotating volumetric module and user calibration.

Key specifications

Channels
8 and 12
8-channel ranges
0.5–10, 2–20, 5–50, 10–100, 20–200, 40–350 µL
12-channel ranges
0.5–10, 5–50, 20–200, 40–350 µL
Catalogue numbers
855.08.010, .020, .050, .100, .200, .350 (8-channel); 855.12.010, .050, .200, .350 (12-channel)
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura manual 855 is a manual multichannel pipette available in 8- and 12-channel versions, with volume ranges from 0.5 to 350 µL. It is designed to extend pipetting into 96-well microplates while keeping the light weight and hand fit of the Acura family.

The volumetric module rotates 360° so the user can choose the best working position, and the tip ejector height can be adjusted over a 4 mm span for sequential tip ejection. A front display shows the set volume, volume is set with fine click-stops, and calibration is carried out with the Swift-Set key. The instrument is autoclavable.

Specifications

Technical specifications

12 parameters

General

Channels
8 and 12
8-channel ranges
0.5–10, 2–20, 5–50, 10–100, 20–200, 40–350 µL
12-channel ranges
0.5–10, 5–50, 20–200, 40–350 µL
Catalogue numbers
855.08.010, .020, .050, .100, .200, .350 (8-channel); 855.12.010, .050, .200, .350 (12-channel)
Tip style
10, 20, 200 and 350 µL by model
Volumetric module
360° rotation
Warranty
3 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 0.5–10 µL
Inaccuracy E% <±3.5 % / <±2.5 % / <±1.5 %; Imprecision CV% <3.0 % / <2.0 % / <1.0 % (min measured at 10 % of nominal)
Accuracy, 2–20 µL (8-ch)
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.2 %; Imprecision CV% <2.0 % / <1.4 % / <0.7 %
Accuracy, 5–50 µL
Inaccuracy E% <±1.0 % / <±0.9 % / <±0.8 %; Imprecision CV% <1.0 % / <0.7 % / <0.4 %
Accuracy, 20–200 µL
Inaccuracy E% <±0.9 % / <±0.8 % / <±0.7 %; Imprecision CV% <0.6 % / <0.5 % / <0.3 %
Accuracy, 40–350 µL
Inaccuracy E% <±1.0 % / <±0.9 % / <±0.8 %; Imprecision CV% <0.6 % / <0.5 % / <0.3 %
Features

Key features

  • 01

    8- and 12-channel models

    Ranges up to 350 µL.

  • 02

    Rotating module

    360° rotation of the volumetric module for the best working position.

  • 03

    Sequential tip ejection

    Adjustable ejector with a shape designed for easy ejection.

  • 04

    Always visible display

    Volume window on the front.

  • 05

    Swift-Set calibration

    Integrated key and sealed locking switch.

  • 06

    Autoclavable

    Shock, UV and chemical resistant.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.