Reference: 865

Socorex Acura self-refill 865 microdispenser pipette

Hand-held self-refilling microdispenser for repeat distribution from 5 to 1000 µL, combining micropipette handling with repeater-style dosing and no consumables.

Key specifications

Volume ranges
5–50 µL, 20–200 µL, 100–1000 µL
Resolution (division)
0.1, 0.2 and 1.0 µL respectively
Catalogue numbers
865.0050, 865.0200, 865.1000
Feeding
Bottle (silicone tubing supplied), vial or syringe
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acura self-refill 865 is a hand-held microdispenser for repeated distribution of microlitre volumes. A three-way valve system refills it automatically, so it handles like a regular micropipette but works like a repeater pipette. Three models cover 5 to 1000 µL.

It can draw from a bottle through the supplied silicone tubing, or from a vial or syringe with accessories. Typical uses named by Socorex include serial tube filling, sample screening and, with an 8-channel manifold, microplate filling. There are no consumables to buy, the valve unit rotates to the best working position, and the instrument can be autoclaved assembled.

Specifications

Technical specifications

10 parameters

General

Volume ranges
5–50 µL, 20–200 µL, 100–1000 µL
Resolution (division)
0.1, 0.2 and 1.0 µL respectively
Catalogue numbers
865.0050, 865.0200, 865.1000
Feeding
Bottle (silicone tubing supplied), vial or syringe
Valves
One intake and one outlet valve
Sterilisation
Autoclavable fully assembled, 121 °C / 250 °F for 20 min
Warranty
3 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 5–50 µL
Inaccuracy E% <±5.0 % / <±3.5 % / <±1.5 %; Imprecision CV% <2.0 % / <1.4 % / <0.4 %
Accuracy, 20–200 µL
Inaccuracy E% <±2.5 % / <±1.8 % / <±1.0 %; Imprecision CV% <1.5 % / <1.0 % / <0.3 %
Accuracy, 100–1000 µL
Inaccuracy E% <±1.5 % / <±1.1 % / <±0.6 %; Imprecision CV% <0.6 % / <0.4 % / <0.2 %
Features

Key features

  • 01

    Self-refilling

    Valve system refills automatically from bottle, vial or syringe.

  • 02

    No consumables

    No tips or syringes to replace.

  • 03

    Rotating valve unit

    Choose the best working position.

  • 04

    Swift-Set calibration

    Integrated key and sealed switch.

  • 05

    Autoclavable

    Sterilise assembled at 121 °C.

  • 06

    Manifold option

    Eight-channel manifold for plate filling.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.