Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 2

Reference: 501

Socorex Acurex compact 501 bottle dispenser

Low-profile reagent bottle dispenser with the dosing mechanism inside the reservoir, 0.2 to 30 mL, suitable for refrigerator storage and water-bath heating.

Key specifications

Volume ranges
0.2–2 mL, 0.4–5 mL, 1–10 mL, 1–30 mL
Resolution (division)
0.1, 0.2, 0.2 and 1.0 mL respectively
Reservoir capacities
250, 500, 1000 and 2000 mL (by model)
Catalogue numbers
501.02025, 501.021, 501.022, 501.0505, 501.051, 501.052, 501.101, 501.102, 501.302
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Acurex compact 501 is a bottle dispenser for safe reagent handling that can be stored in a refrigerator or heated in a water bath. The dosing mechanism sits entirely inside the reservoir, and the graduated column retracts to reduce the overall height.

Four volume ranges from 0.2 to 30 mL are offered, with reservoir sizes from 250 mL to 2000 mL depending on the model. The fluid path contains no metal, the construction is simple and robust, and the instrument can be autoclaved fully assembled.

Specifications

Technical specifications

8 parameters

General

Volume ranges
0.2–2 mL, 0.4–5 mL, 1–10 mL, 1–30 mL
Resolution (division)
0.1, 0.2, 0.2 and 1.0 mL respectively
Reservoir capacities
250, 500, 1000 and 2000 mL (by model)
Catalogue numbers
501.02025, 501.021, 501.022, 501.0505, 501.051, 501.052, 501.101, 501.102, 501.302
Fluid path
No metal
Sterilisation
Fully autoclavable, 121 °C / 250 °F for 20 min
Warranty
2 years

Performance (ISO 8655, bidest. water, 20-25 °C)

Imprecision CV%
<0.5 % min / <0.35 % mid / <0.1 % max volume (all ranges)
Features

Key features

  • 01

    Refrigerator storage

    Low profile fits cold storage of sensitive reagents.

  • 02

    Retractable column

    Reduces instrument height.

  • 03

    Metal-free fluid path

    No metal in contact with the liquid.

  • 04

    Four reservoir sizes

    250 to 2000 mL.

  • 05

    Autoclavable

    Sterilise fully assembled at 121 °C.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.