Socorex Dosys basic 162 syringe pipette

Automatic two-ring syringe pipette without valve system and with Luer Lock nozzle, 0.1 to 5 mL, for dispensing and sampling of aqueous, non-corrosive liquids.

Key specifications

Handle
Two-ring
Valve system
None; Luer Lock nozzle
Volume ranges
0.1–1 mL, 0.3–2 mL, 0.5–5 mL
Resolution (division)
0.05, 0.1 and 0.5 mL respectively
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Dosys basic 162 is an automatic, two-ring syringe pipette without a valve system, with a Luer Lock nozzle and volumes from 0.1 to 5 mL in three models. Socorex recommends it for aqueous, non-corrosive liquids in general laboratory work.

Spring-assisted aspiration and distribution both take place through the cannula, which makes it suitable for dose-by-dose sampling. Volume is set within seconds with a micrometric screw and safety-locking nut. It is supplied with a PVC protection sleeve for the glass barrel.

Specifications

Technical specifications

9 parameters

General

Handle
Two-ring
Valve system
None; Luer Lock nozzle
Volume ranges
0.1–1 mL, 0.3–2 mL, 0.5–5 mL
Resolution (division)
0.05, 0.1 and 0.5 mL respectively
Catalogue numbers
162.0501, 162.0502, 162.0505
Warranty
1 year

Performance (bidest. water, 1.2 x 50 mm steel cannula)

Imprecision CV%, 0.1–1 mL
<0.7 % / <0.6 % / <0.4 %
Imprecision CV%, 0.3–2 mL
<0.6 % / <0.5 % / <0.4 %
Imprecision CV%, 0.5–5 mL
<0.5 % / <0.4 % / <0.2 %
Features

Key features

  • 01

    Ergonomic handle

    Balanced shape for long dispensing series.

  • 02

    Fast volume setting

    Micrometric screw with safety-locking nut keeps the setting fixed.

  • 03

    No plunger O-ring

    Stainless steel plunger in a ground glass barrel.

  • 04

    Easy maintenance

    Six main parts that are quick to disassemble.

  • 05

    Autoclavable

    Fully assembled at 121 °C / 250 °F, without the PVC protection sleeve.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.