Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 2

Reference: 163

Socorex Dosys classic 163 syringe pipette

Self-refilling two-ring automatic syringe pipette with integrated Luer Lock valve system, 0.025 to 10 mL, for dispensing, sterile work, filtration and aspiration.

Key specifications

Handle
Two-ring
Valve system
Self-refilling, integrated Luer Lock valve
Volume ranges
0.025–0.3, 0.1–0.5, 0.1–1, 0.3–2, 0.5–5 and 1–10 mL
Resolution (division)
0.025, 0.1, 0.05, 0.1, 0.5 and 1 mL respectively
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Dosys classic 163 is a self-refilling automatic syringe pipette with a two-ring handle and an integrated Luer Lock valve system. Six models cover 0.025 to 10 mL, and Socorex recommends it for aqueous, non-corrosive liquids.

A spring-loaded plunger and three-way valve allow trouble-free distribution, with feed tubing supplied and bottle feeding optional. The instrument and its accessories can be autoclaved assembled, which makes it useful for hot agar and culture media. With a sterile filter disk it works as a filtration syringe, with a reverse-mode valve set it aspirates waste, and with suitable needles it can be used for injecting laboratory animals.

Specifications

Technical specifications

12 parameters

General

Handle
Two-ring
Valve system
Self-refilling, integrated Luer Lock valve
Volume ranges
0.025–0.3, 0.1–0.5, 0.1–1, 0.3–2, 0.5–5 and 1–10 mL
Resolution (division)
0.025, 0.1, 0.05, 0.1, 0.5 and 1 mL respectively
Catalogue numbers
163.05003, 163.05005, 163.0501, 163.0502, 163.0505, 163.0510
Warranty
1 year

Performance (bidest. water, 1.2 x 50 mm steel cannula)

Imprecision CV%, 0.025–0.3 mL
<1.8 % (at 0.075 mL) / <1.2 % / <0.5 %
Imprecision CV%, 0.1–0.5 mL
<1.2 % / <0.9 % / <0.4 %
Imprecision CV%, 0.1–1 mL
<0.7 % / <0.6 % / <0.4 %
Imprecision CV%, 0.3–2 mL
<0.6 % / <0.5 % / <0.4 %
Imprecision CV%, 0.5–5 mL
<0.5 % / <0.4 % / <0.2 %
Imprecision CV%, 1–10 mL
<0.5 % / <0.4 % / <0.2 %
Features

Key features

  • 01

    Dispensing and distribution

    Spring-loaded plunger and three-way valve, with feed tubing supplied.

  • 02

    Sterile work

    Autoclavable assembled; suited to hot agar and culture media.

  • 03

    Filtration

    Sterile filter disk on the outlet valve turns it into a filtration syringe.

  • 04

    Aspiration

    Reverse-mode valve set for waste collection.

  • 05

    Animal injection

    Used with suitable needles and drenchers.

  • 06

    Fast volume setting

    Micrometric screw with safety-locking nut keeps the setting fixed.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.