Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 2

Reference: 316

Socorex Ecostep syringes for Stepper repeater pipettes

Disposable colour-coded syringes for the Stepper repeater pipette in three sizes covering 10 to 5000 µL, in non-sterile and sterilised bioproof versions.

Key specifications

Sizes
0.75 mL yellow (10–100 µL), 3.75 mL blue (50–500 µL), 37.5 mL red (500–5000 µL)
Non-sterile (100 per pack)
316.010, 316.050, 316.500
Sterilised bioproof (50 per pack)
316.010.9, 316.050.9, 316.500.9
Selection packs (60 per pack)
316.900 non-sterile; 316.900.9 sterilised
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Ecostep syringes are the disposable positive displacement syringes used by the Stepper repeater pipette. Three sizes cover the full 10 to 5000 µL range: 0.75 mL (yellow), 3.75 mL (blue) and 37.5 mL (red). Colour coding on the syringe matches the selector button to avoid setting errors, and the graduation shows the remaining liquid.

They are available non-sterile in bulk packs, or sterilised and single wrapped in a bioproof version whose batches are certified free of human DNA, DNase, RNase and pyrogens. Selection packs contain 20 of each size. They fit all Stepper generations.

Specifications

Technical specifications

9 parameters

General

Sizes
0.75 mL yellow (10–100 µL), 3.75 mL blue (50–500 µL), 37.5 mL red (500–5000 µL)
Non-sterile (100 per pack)
316.010, 316.050, 316.500
Sterilised bioproof (50 per pack)
316.010.9, 316.050.9, 316.500.9
Selection packs (60 per pack)
316.900 non-sterile; 316.900.9 sterilised
Bioproof certification
Each batch certified human DNA, DNase, RNase and pyrogen (endotoxin) free by independent laboratories
Compatibility
Fits all Stepper generations

Performance (ISO 8655, bidest. water, 20-25 °C)

Accuracy, 10–100 µL syringe
Inaccuracy E% <±1.5 % at 20 µL, <±1.0 % at 100 µL; Imprecision CV% <1.5 % at 20 µL, <0.8 % at 100 µL (non-sterile)
Accuracy, 50–500 µL syringe
Inaccuracy E% <±1.0 % at 100 µL, <±0.5 % at 500 µL; Imprecision CV% <1.0 % at 100 µL, <0.5 % at 500 µL
Accuracy, 500–5000 µL syringe
Inaccuracy E% <±0.8 % at 1000 µL, <±0.5 % at 5000 µL; Imprecision CV% <0.7 % at 5000 µL
Features

Key features

  • 01

    Colour coding

    Matches the Stepper selector buttons.

  • 02

    Graduated barrel

    Shows remaining liquid.

  • 03

    Non-sterile bulk packs

    100 per pack.

  • 04

    Sterile bioproof version

    Single wrapped, certified DNA/RNase/pyrogen free.

  • 05

    Selection packs

    20 of each size.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.