Skip to content
Al-Shaker for Scientific and Medical Supplies

Socorex Profiller electro 447

Electronic pipette controller for glass or plastic pipettes to 100 mL: 25 mL in 3 s, ~6 h Li-ion, TC/TD modes, for a laminar-flow cabinet.

Key specifications

Capacity
Glass or plastic pipettes to 100 mL and over
Speed
Fills 25 mL in 3 s
Runtime
About 6 h; Li-ion, charge while in use
Cover
One year
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Profiller™ electro 447 is Socorex’s pipette controller for serological and volumetric pipettes in a cabinet: a quiet motor that fills 25 mL in about three seconds, a shape that fits a gloved hand, and a large display that stays readable. From June 2025 the pack is Li-ion, about six hours of work, chargeable in storage or while you pipette, with a live charge indicator. A switch selects blow-out (TC) or gravity (TD) and fast or slow aspiration/dispense. Two finger triggers give gradual speed. Hydrophobic membrane filters (0.45 µm and 0.2 µm supplied) swap when they wet. Shock- and chemical-resistant housing. Cat. no. 447.100 includes the supply with EU/US-JP/GB/AUS-NZ plugs, two spare filters, bench stand, wall hanger, and a quick guide — no plug country to specify. One-year warranty.

Al-Shaker specifies 447 for cell culture, media, and environmental volumes that a micropipette should not see, then supports the controller. Manual Profiller 437 and Profilette 406 are available as accessories. Filters and stands are consumables.

Specifications

Technical specifications

4 parameters

Capacity
Glass or plastic pipettes to 100 mL and over
Speed
Fills 25 mL in 3 s
Runtime
About 6 h; Li-ion, charge while in use
Cover
One year
Features

Key features

  • 01

    TC or TD, fast or slow

    Blow-out or gravity, two speeds on the display, triggers that meter the flow instead of dumping it.

  • 02

    Li-ion, charge in the hand

    Six hours, plug on the instrument, charge level on the screen — including during a run.

  • 03

    Filters you can swap

    0.45 µm and 0.2 µm hydrophobic membranes so a suck-back does not reach the pump.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.