Reference: NIMBUS

NIMBUS laboratory ultrasonic extinction analyser

Compact table-top ultrasonic extinction analyser for particle size and concentration of concentrated suspensions and emulsions from below 0.1 to 3,000 µm.

Key specifications

Measuring principle
Ultrasonic extinction, 31 discrete frequencies
Measuring range
< 0.1 - 3,000 µm
Max. concentration
40 vol%
Analysis volume
250 - 1,000 ml
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

NIMBUS is a compact table-top instrument that brings ultrasonic extinction to the laboratory for individual low-viscosity samples. Sound waves are sent through the sample at 31 discrete frequencies, and the measured attenuation is converted into a particle size distribution with 31 reference points, plus concentration.

Because it uses sound instead of light, concentrated and optically opaque suspensions and emulsions up to 40 vol% can be measured in their original state without dilution. A centrifugal pump circulates 250 to 1,000 ml of sample in a closed stainless-steel circuit, and the lowerable basin floor allows quick draining and cleaning.

Specifications

Technical specifications

6 parameters

Measurement

Measuring principle
Ultrasonic extinction, 31 discrete frequencies
Measuring range
< 0.1 - 3,000 µm
Max. concentration
40 vol%

Sample

Analysis volume
250 - 1,000 ml
Max. product temperature
50 °C

Materials

Wetted parts
Stainless steel (1.4571, 1.4308, 1.4301, 1.4112), vitreous carbon windows, FKM seals (optional EPDM, NBR, FFKM), PTFE and polyamide 12 G
Features

Key features

  • 01

    Acoustic principle

    Independent of sample transparency.

  • 02

    High concentration

    Suspensions and emulsions up to 40 vol%.

  • 03

    Closed circuit

    250 to 1,000 ml analysis volume.

  • 04

    Chemically resistant

    Stainless steel, vitreous carbon and PTFE wetted parts.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support