Skip to content
Al-Shaker for Scientific and Medical Supplies

Galaxy Scientific QuasIR 2000

Portable fiber-optic FT-NIR for lab, process, and field — SMA 905 probes for reflection, transmission, or transflectance of liquids or solids.

Key specifications

Interface
Fiber-optic probes (SMA 905)
Modes
Reflection, transmission, or transflectance
Targeted screening
Advanced-ID
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The QuasIR 2000 is a portable fiber-optic FT-NIR. Standard SMA 905 connectors accept commercial probes as well as Galaxy’s own diffuse-reflectance probe (patterned fiber layout for better probe-to-probe reproducibility). Reflection, transmission, or transflectance probes cover liquids and solids at the bench or in a process.

PermAlign optics keep performance when the spectrometer is moved to the point of need. Advanced-ID software supports low-concentration targeted screening. Optional Symbion DX and RX process software can manage online measurement. Spectral Sage remains the everyday method and QC environment.

Al-Shaker specifies the QuasIR 2000 when the sample cannot come to a chamber — tanks, lines, and field points — and the QuasIR 2000E when the measurement must run continuously on a conveyor, pipe, or chute.

Specifications

Technical specifications

3 parameters

Sampling

Interface
Fiber-optic probes (SMA 905)
Modes
Reflection, transmission, or transflectance

Software

Targeted screening
Advanced-ID
Features

Key features

  • 01

    SMA 905 fiber probes

    Reflection, transmission, or transflectance probes — including Galaxy’s patterned diffuse-reflectance probe.

  • 02

    Point-of-need FT-NIR

    PermAlign keeps alignment when the spectrometer leaves the bench for the plant or the field.

  • 03

    Advanced-ID screening

    Targeted low-concentration screening on top of Spectral Sage QC methods.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.