Analytical and precision laboratory balances in Jordan

Choose a laboratory balance by readability (the smallest weight it displays) and capacity (the heaviest load). Analytical balances read to 0.1 mg or finer for quantitative work; precision balances read to 1 mg to 0.1 g for general weighing. Match both to your tolerances.

In our catalog

Laboratory balances

24 products from ViBRA
ViBRA HT Analytical Balances
ViBRA

ViBRA HT Analytical Balances

0.1 mg analytical balances, 80–220 g, 3 s stabilisation — Shinko Denshi’s tuning-fork sensor, the only analytical balance of its kind.

View product

ViBRA AJ / AJH Precision Balances
ViBRA

ViBRA AJ / AJH Precision Balances

Tuning-fork precision balances from 220 g / 0.001 g to 12 kg / 0.1 g — compact chassis, optional internal calibration on AJH, OIML Class I/II.

View product

ViBRA MD Moisture Analysers
ViBRA

ViBRA MD Moisture Analysers

Loss-on-drying moisture: 80 g / 0.005 g / 0.01 %, organic-carbon heater 2 × 280 W, 30–180 °C — automatic or timed end-point.

View product

ViBRA LF Series Analytical Balances
ViBRA

ViBRA LF Series Analytical Balances

Semi-micro and analytical balances from ViBRA with automatic span adjustment, a combination windshield door and a back-lit display, covering 92 g to 220 g.

View product

How to choose: Laboratory balances

  1. 01

    Readability

    Pick readability about ten times finer than the tolerance you must prove. Over-specifying costs more and makes the balance harder to keep stable.

  2. 02

    Capacity

    Capacity must exceed your heaviest container plus sample. Tuning-fork and strain-gauge designs trade off speed, cost and resolution.

  3. 03

    Environment

    Vibration, drafts and temperature swings affect weighing. Choose a draft shield, an anti-vibration bench and a stable location.

  4. 04

    Calibration

    Internal calibration reduces drift; regulated work still needs periodic certified external calibration and routine checks with test weights.

  5. 05

    Special cases

    IP65 stainless models for wash-down areas, ATEX/IECEx versions for hazardous zones, and legal-for-trade approval for commercial weighing.

Typical applications

  • Pharmaceutical QC and formulation
  • Food, agriculture and moisture content testing
  • Chemical and teaching laboratories
  • Jewellery and commercial weighing (legal-for-trade)
  • Hazardous areas (explosion-proof)

Manufacturers we supply for this equipment

Each range is supplied with installation, operator training and local service.

Frequently asked questions

What is the difference between analytical and precision balances?

Analytical balances read to 0.1 mg or finer and usually have a draft shield; they are used for accurate quantitative analysis. Precision balances read from about 1 mg to 0.1 g and handle larger loads for general laboratory weighing.

How often should a balance be calibrated?

Perform routine checks with test weights daily or per use, and schedule certified calibration at least annually, or as your quality system requires.

Does Al-Shaker supply certified calibration for balances in Jordan?

Al-Shaker supplies ViBRA balances with installation, training and support. Ask the technical team about calibration and maintenance contract options for your site.

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.