SCION 8700 SQ GC-MS
Single-quadrupole GC-MS with EI and CI, EDR detection, and a 90° Q0 — couples to the 8300 or 8500 GC as a standalone MS or an extra detector.
View product
Equipment guide
Gas chromatography separates volatile compounds in a heated column, and a detector identifies or measures them. Choose the detector by the question (FID for hydrocarbons, ECD for halogens, mass spectrometry for identification), then plan carrier-gas supply and service early.

Single-quadrupole GC-MS with EI and CI, EDR detection, and a 90° Q0 — couples to the 8300 or 8500 GC as a standalone MS or an extra detector.
View product

Triple-quadrupole GC-MS at 30,000 Da/s and 1,000 MRM/s — SCION’s quantitative GC-MS for residue, toxicology, and multi-analyte methods.
View product

European-built gas chromatographs: the 32 cm 8300 for two-channel work including MS, and the 8500 when the oven and detector count have to grow.
View product

Modular HPLC with a 6100 quaternary pump (HFM), 6210/6220 autosampler, Peltier ovens, and UV/DAD/FL/RI — CompassCDS with 21 CFR Part 11 tools.
View product

Versa 20-position static, HT3 60-position static, and HT3 dynamic with a multi-bed trap — residual solvents, flavours, and VOCs without a solvent extraction.
View product

GBC gas chromatograph: TCD, FID, FPD, NPD, ECD; up to 3 columns and 3 detectors; 10-segment oven; digital pressure 0.1 psi.
View product

Automated gas chromatograph from SCION Instruments built for accurate, repeatable analysis across routine QC and application-specific work, with a choice of two in-house autosamplers.
View product

Robust SCION Instruments gas chromatograph for 24/7 operation, available with 8400PRO or 8410PRO autosamplers and configurable for standard-method or custom analysers.
View product

Automated headspace sampler from SCION Instruments with 60-position autosampler, heating up to 300 °C and an optional dynamic mode that raises sensitivity 50 to 100 times.
View product

Compact 20-position static headspace sampler from SCION Instruments, only 12 inches wide, with 22 mL vials, heated pathway to 200 °C and inert sample path.
View product

Turn-key amino acid analyzer from SCION Instruments with pre-tuned inject-and-run methods, 8 pMol detection limit and 21 CFR Part 11 compliant data system.
View product

Chromatography data system from SCION Instruments that controls GC and LC instruments from several vendors, from single workstation to enterprise client/server, with 21 CFR Part 11 support.
View product
FID for general organics, ECD for halogenated compounds, TCD for permanent gases, and single or triple quadrupole MS when you must identify unknowns or reach trace limits.
Split/splitless for liquids, headspace for residual solvents and volatiles, thermal desorption for air. An autosampler is the biggest throughput gain.
Helium, hydrogen or nitrogen carrier plus FID gases drive running cost. On-site hydrogen and zero-air generators avoid cylinder logistics.
Factory-configured analysers for ASTM or ISO methods shorten validation for petrochemical and fuel testing.
Check local service engineers, spare parts availability, and software that supports audit trails if you work under GLP or GMP.
Each range is supplied with installation, operator training and local service.
A GC with a conventional detector (such as FID) quantifies compounds by retention time. GC-MS adds a mass spectrometer that identifies each compound by its mass spectrum, which is essential for unknowns, confirmation and trace-level work.
Yes. Hydrogen and zero-air generators supply FID and carrier gas on demand, removing cylinder deliveries and giving constant purity. Helium alternatives such as hydrogen or nitrogen need method re-validation.
Yes. Installation, commissioning, operator training and maintenance contracts are delivered by the Al-Shaker technical team across Jordan and MENA.
Talk to the technical team
Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.