Socorex Acura manual pipettes
Swiss-made manual micropipettes: 825 for daily work, 826 XS for research, 835 macropipettes, 855 multichannel — Justip™ ejector, Swift-set calibration, three-year warranty.
View product
Industry solutions
Equipping environmental labs with robust analytical instruments for monitoring pollutants and ensuring the safety of our water and soil. Our solutions provide the accuracy needed for critical environmental assessment. Featured solutions for this sector: SCION GC systems, Meslo general laboratory equipment, GBC atomic absorption and ICP-OES, and Biocomma SPE and kits.
GC-MS for pesticides, VOCs and hydrocarbons, with headspace and thermal-desorption sampling as needed.
ICP-OES, ICP-MS or atomic absorption, matched to detection limits and sample throughput.
Ion chromatography for nitrate, sulphate, chloride and other ions in drinking and waste water.
Cooled incubators and autoclaves for BOD tests and microbiological water analysis.
Gas generators and recirculating chillers keep GC and ICP systems running without cylinder logistics.

Swiss-made manual micropipettes: 825 for daily work, 826 XS for research, 835 macropipettes, 855 multichannel — Justip™ ejector, Swift-set calibration, three-year warranty.
View product

Single-quadrupole GC-MS with EI and CI, EDR detection, and a 90° Q0 — couples to the 8300 or 8500 GC as a standalone MS or an extra detector.
View product

Double-beam AAS from GBC Scientific Equipment: Ebert-Fastie 333 mm, 175–900 nm, 1800 line/mm, 8-lamp turret, Hyper-Pulse background correction.
View product

WITec confocal Raman imaging: Hexalight spectrometer 350–1100 nm, up to six gratings, correlative AFM/SEM/fluorescence — chemical maps at the nanoscale, not a point-and-shoot Raman probe.
View product

Modular and integrated ion chromatographs for anions, cations, transition metals, organic acids, and amines.
View product

Micro Clima BR1/BR2 and EB1/EB2 cooled incubators and incubator walls — quiet, practical cabinets tested at least two weeks in Tilburg before they ship.
View product

NIMBUS laboratory and OPUS process analysers for particle size and concentration in suspensions and emulsions from below 0.1 µm to 3,000 µm.
View product

Portable fiber-optic FT-NIR for lab, process, and field — SMA 905 probes for reflection, transmission, or transflectance of liquids or solids.
View product
Atomic absorption, ICP-OES or ICP-MS. AAS suits a few elements, ICP-OES many elements at once, and ICP-MS ultra-trace levels. The regulation you test against sets the required detection limit.
Ion chromatography separates anions such as chloride, nitrate and sulphate on an ion-exchange column and measures them with a conductivity detector.
Yes. Turnkey laboratory planning covers consultation, equipment selection, supply, installation and training through to handover.
Talk to the technical team
Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.